Description
Surplus Equipment: GS E&C 10 Tons Overhead Crane (1 unit)
Details:
- Manufacturer: GS Engineering & Construction
- Capacity: 10 tons / 21.9 meters overhead crane-hoisting
- Year of Manufacture: 2017
- Service: Crane for Warehouse
Motor Datasheets
A. GENERAL | C. VENDOR’S DATA | |||||
---|---|---|---|---|---|---|
1. DRIVEN EQUIPMENT: | 10ton x Span 21.9 m | 1. MANUFACTURER: | NAMSUNG MACHINERY | |||
2. AMBIENT TEMPERATURE: | MAX. 45ºC / MIN. 2ºC | 2. FRAME REFERENCE: | 180L | |||
3. RELATIVE HUMIDITY: | MAX. 85% / MIN. – % | 3. FRAME MATERIAL: | FC 200 | |||
4. ALTITUDE (SEA LEVEL): | LESS THAN 1000 METERS | 4. FULL LOAD SPEED: | 720 RPM | |||
5. APPLICABLE STD.: | IEC 60034, 60072 and 60079 | 5. LOAD: | 50% | 75% | 100% | S.F |
6. PROJECT SPEC.: | 7T04-EL-00-TS-008 | EFFICIENCY [%]: | 73 | 76 | 78.6 | 1.0 |
7. AREA CLASSIFICATION: | NON-HAZARDOUS | POWER FACTOR [%] | 46 | 60 | 66.3 | 1.0 |
8. SYSTEM FAULT LEVEL: | 80 kA / 1 sec. | CURRENT [A] | 16 | 18 | 21 | 1.0 |
9. SYSTEM EARTHING: | SOLID | 6. ACCELERATION TIME: | 0.3 sec. | |||
10. DESIGN LIFE: | MINIMUM 20 YEARS | 7. FULL-LOAD TORQUE: | 10.146 kg m | |||
B. MOTOR DESIGN DATA | 8. LOCKED ROTOR TORQUE: | 228% | ||||
1. MOTOR RATING: | See Note 1 | 9. PULL-UP TORQUE: | 290% | |||
NAMEPLATE RATING: | 7.5 kW | 8 POLES | 10. BREAK-DOWN TORQUE: | 290.2% | |||
RATED VOLTAGE: | 400 V, 3 PHASE, 50 HZ See Note 2 | 11. LOCKED ROTOR CURRENT: | 110.5 A | |||
SERVICE FACTOR: | 1.0 SYNC. SPEED 720 RPM | 12. LOCK. ROTOR PWR FACTOR: | 26% | |||
2. MOTOR TYPE: | SQUIRREL CAGE INDUCTION | 13. STALL TIME (HOT/COLD): | 0.7 sec. | |||
3. OPERATION DUTY: | S4 INTERMITTENT | 14. TRANSIENT REACTANCE (X’d): | N/A | |||
4. ENCLOSURE TYPE: | IP55 | 15. SUB-TRANSIENT REACTANCE (X’d): | N/A | |||
5. COOLING METHOD: | ( ) TENV | (X) TEFC | ( ) CACA | ( ) TEWAC | 16. SPACE HEATER RATING: | N/A V | N/A W | |||
6. TYPE OF PROTECTION REQ’D: | ( ) TYPE n (Exn) | ( ) TYPE p (Exp) | 17. INSULATION CLASS/TEMP. RISE: | F/75ºC | |||
( ) TYPE e (Exe) | ( ) TYPE d (Exd) | 18. STATOR CONNECTION: | Star | ||||
7. STARTING METHOD: | (X) DOL | ( ) AUTO-TRANS. | 19. TEMP. DETECTOR (WIND./BEARING): | N/A | |||
8. PROTECTION DEVICES: | ( ) FUSE | (X) C.B | 20. VIBRATION DETECTOR: | N/A | |||
9. MOUNTING: | (X) HORIZONTAL | ( ) VERTICAL | 21. MOTOR WEIGHT (NET/SHIPPED): | 280 kg | |||
( ) FOOT | 22. ROTOR/LOAD MOMENT OF INERTIA: | 0.673 / 0.742 kg.m2 | ||||
10. DRIVE SYSTEM: | (X) DIRECT | ( ) GEAR UNIT | 23. BEARING REF. (DE/NDE): | #6309DD / #6208DD | |||
( ) V-BELTS | 24. BEARING TYPE: | ANTI-FRICCIONAL (BALL) | ||||
11. INSULATION CLASS: | (X) F | 25. BEARING LUBRIFICATION: | GREASE | |||
12. TEMP. RISE WITHIN CLASS: | ( ) E | (X) B | 26. BEARING LUBRIFICATION INTERVAL: | 30,000 HOURS | |||
13. MAIN TERMINAL BOX LOCATION: | (X) RIGHT | ( ) LEFT | 27. NUMBER OF CONSECUTIVE STARTS: | 2 HOT / 3 COLD | |||
14. ROTATION: | (X) CCW | (X) CW | 28. REQUIRED AIR FOR PURGE: | ||||
15. SPACE HEATER SUPPLY: | N/A | @STARTING (PURGING) | N/A Nm3/min @ N/A bar | |||
16. MAIN CABLE ENTRY: | (X) SIDE | ( ) BOTTOM | @OPERATING | N/A Nm3/min @ N/A bar | |||
17. CABLE CONNECTION: | M25 | 29. Void | ||||
18. CABLE TYPE & SIZE (MOTOR): | M32 | 30. TIME CONSTANTS (HEATING/COOLING) | N/A sec. | |||
19. CABLE TYPE & SIZE (S.H): | TFR-CV 6SQ | D. ADDITIONAL INFORMATION FURNISHED BY VENDOR | ||||
20. SOUND PRESSURE LEVEL: | 67 dB Mean. @ 1 meter ON NO LOAD | [V] TORQUE/SLIP, CURRENT/SLIP, POWER FACTOR/SLIP CURVES | ||||
21. FRAME EARTH BOSS: | INTERNAL & EXTERNAL | [N/A] TIME – CURRENT and THERMAL LIMIT CURVES | ||||
22. COLOR FINISHING: | RAL 6028 | [N/A] MOTOR THERMAL CAPACITY DATA | ||||
23. TEMPERATURE DETECTION: | N/A | [V] INSTALLATION, OPERATION & MAINTENANCE INSTRUCTION | ||||
24. VIBRATION DETECTION: | N/A | [V] RECOMMENDED SPARE PARTS LIST | ||||
25. SURGE WITHSTAND EQUIPMENT.: | N/A | [V] DIMENSIONAL OUTLINE DRAWING | ||||
26. MAX. STARTING CURRENT: | 526.2% | [V] CERTIFIED TEST REPORT & WRITTEN STATEMENT | ||||
27. SPECIAL REQUIREMENTS: | N/A | [V] COMPLETE NAMEPLATE DATA | ||||
28. CORE BALANCE CR: | N/A (See Note 6) | [V] SEE INDUCTION MOTORS SPECIFICATION FOR DETAIL | ||||
E. OTHERS (BY VENDOR) | ||||||
1. ACOUSTIC HOOD FITTED | (X) NO | ( ) YES | |||||
2. CERTIFICATION AUTHORITY | N/A | |||||
F. NOTES | 2. CERT. STANDARD & NUMBER | N/A | ||||
1. (*) VENDOR TO CONFIRM | ||||||
2. RATED VOLTAGE: UP TO 150 kW: 400 V | OVER 150 kW ~ BELOW 3000 kW: 6.6 kV | 3000 kW AND ABOVE: 11 kV | ||||||
3. SPACE HEATERS ARE REQUIRED FOR 30 kW AND ABOVE | ||||||
4. 6 RTD (2 SETS PER PHASE – 3 WIRE TYPE 100 OHM) WINDING TEMPERATURE DETECTOR SHALL BE REQUIRED FOR MV MOTORS 1000 kW and LARGER | ||||||
5. VENDOR SHALL COMPLY WITH THE ATTACHED MOTOR TERMINAL BOX HUB SIZE | ||||||
6. MOTORS 3000 kW AND LARGER SHALL BE PROVIDED WITH CORE BALANCE CURRENT TRANSFORMER FOR DIFFERENTIAL PROTECTION | ||||||
7. LRC LIMITING: UP TO 150 kW MOTOR: 600% WITH IEC TOLERANCE, ABOVE 150 kW ~ UP TO 2000 kW: 550% WITH IEC TOLERANCE, ABOVE 2000 kW: ONLY 450% WITHOUT IEC TOLERANCE | ||||||
8. MOTOR SHALL BE EQUIPPED WITH A CANOPY UNLESS AN AIR DUCT, COOLER, OR SILENCER WHICH IS EFFECTIVE FOR A CANOPY IS PROVIDED ON THE TOP MOTOR |
A. GENERAL | C. VENDOR’S DATA | |||||
---|---|---|---|---|---|---|
1. DRIVEN EQUIPMENT: | 10ton x Span 21.9 m | 1. MANUFACTURER: | NAMSUNG MACHINERY | |||
2. AMBIENT TEMPERATURE: | MAX. 45ºC / MIN. 2ºC | 2. FRAME REFERENCE: | 90L | |||
3. RELATIVE HUMIDITY: | MAX. 85% / MIN. – % | 3. FRAME MATERIAL: | FC 200 | |||
4. ALTITUDE (SEA LEVEL): | LESS THAN 1000 METERS | 4. FULL LOAD SPEED: | 717 RPM | |||
5. APPLICABLE STD.: | IEC 60034, 60072 and 60079 | 5. LOAD: | 50% | 75% | 100% | S.F |
6. PROJECT SPEC.: | 7T04-EL-00-TS-008 | EFFICIENCY [%]: | 49 | 52 | 54.6 | 1.0 |
7. AREA CLASSIFICATION: | NON-HAZARDOUS | POWER FACTOR [%] | 35 | 46 | 53.2 | 1.0 |
8. SYSTEM FAULT LEVEL: | 80 kA / 1 sec. | CURRENT [A] | 2.8 | 3.1 | 4.6 | 1.0 |
9. SYSTEM EARTHING: | SOLID | 6. ACCELERATION TIME: | 0.3 sec. | |||
10. DESIGN LIFE: | MINIMUM 20 YEARS | 7. FULL-LOAD TORQUE: | 1.25 kg m | |||
B. MOTOR DESIGN DATA | 8. LOCKED ROTOR TORQUE: | 232% | ||||
1. MOTOR RATING: | See Note 1 | 9. PULL-UP TORQUE: | 190% | |||
NAMEPLATE RATING: | 0.92 kW | 8 POLES | 10. BREAK-DOWN TORQUE: | 209% | |||
RATED VOLTAGE: | 400 V, 3 PHASE, 50 HZ See Note 2 | 11. LOCKED ROTOR CURRENT: | 22 A | |||
SERVICE FACTOR: | 1.0 SYNC. SPEED 717 RPM | 12. LOCK. ROTOR PWR FACTOR: | 23% | |||
2. MOTOR TYPE: | SQUIRREL CAGE INDUCTION | 13. STALL TIME (HOT/COLD): | 0.7 sec. | |||
3. OPERATION DUTY: | S4 INTERMITTENT | 14. TRANSIENT REACTANCE (X’d): | N/A | |||
4. ENCLOSURE TYPE: | IP55 | 15. SUB-TRANSIENT REACTANCE (X’d): | N/A | |||
5. COOLING METHOD: | (X) TENV | ( ) TEFC | ( ) CACA | ( ) TEWAC | 16. SPACE HEATER RATING: | N/A V | N/A W | |||
6. TYPE OF PROTECTION REQ’D: | ( ) TYPE n (Exn) | ( ) TYPE p (Exp) | 17. INSULATION CLASS/TEMP. RISE: | F/75ºC | |||
( ) TYPE e (Exe) | ( ) TYPE d (Exd) | 18. STATOR CONNECTION: | Star | ||||
7. STARTING METHOD: | (X) DOL | ( ) AUTO-TRANS. | 19. TEMP. DETECTOR (WIND./BEARING): | N/A | |||
8. PROTECTION DEVICES: | ( ) FUSE | (X) C.B | 20. VIBRATION DETECTOR: | N/A | |||
9. MOUNTING: | (X) HORIZONTAL | ( ) VERTICAL | 21. MOTOR WEIGHT (NET/SHIPPED): | 58 kg | |||
( ) FOOT | 22. ROTOR/LOAD MOMENT OF INERTIA: | 0.088 / 0.104 kg.m2 | ||||
10. DRIVE SYSTEM: | (X) DIRECT | ( ) GEAR UNIT | 23. BEARING REF. (DE/NDE): | #6206DD / #6206DD | |||
( ) V-BELTS | 24. BEARING TYPE: | ANTI-FRICCIONAL (BALL) | ||||
11. INSULATION CLASS: | (X) F | 25. BEARING LUBRIFICATION: | GREASE | |||
12. TEMP. RISE WITHIN CLASS: | ( ) E | (X) B | 26. BEARING LUBRIFICATION INTERVAL: | 30,000 HOURS | |||
13. MAIN TERMINAL BOX LOCATION: | (X) RIGHT | ( ) LEFT | 27. NUMBER OF CONSECUTIVE STARTS: | 2 HOT / 3 COLD | |||
14. ROTATION: | (X) CCW | (X) CW | 28. REQUIRED AIR FOR PURGE: | ||||
15. SPACE HEATER SUPPLY: | N/A | @STARTING (PURGING) | N/A Nm3/min @ N/A bar | |||
16. MAIN CABLE ENTRY: | (X) SIDE | ( ) BOTTOM | @OPERATING | N/A Nm3/min @ N/A bar | |||
17. CABLE CONNECTION: | M25 | 29. Void | ||||
18. CABLE TYPE & SIZE (MOTOR): | TFR-CV 2.5SQ | 30. TIME CONSTANTS (HEATING/COOLING) | N/A sec. | |||
19. CABLE TYPE & SIZE (S.H): | N/A | D. ADDITIONAL INFORMATION FURNISHED BY VENDOR | ||||
20. SOUND PRESSURE LEVEL: | 58 dB Mean. @ 1 meter ON NO LOAD | [V] TORQUE/SLIP, CURRENT/SLIP, POWER FACTOR/SLIP CURVES | ||||
21. FRAME EARTH BOSS: | INTERNAL & EXTERNAL | [N/A] TIME – CURRENT and THERMAL LIMIT CURVES | ||||
22. COLOR FINISHING: | RAL 6028 | [N/A] MOTOR THERMAL CAPACITY DATA | ||||
23. TEMPERATURE DETECTION: | N/A | [V] INSTALLATION, OPERATION & MAINTENANCE INSTRUCTION | ||||
24. VIBRATION DETECTION: | N/A | [V] RECOMMENDED SPARE PARTS LIST | ||||
25. SURGE WITHSTAND EQUIPMENT.: | N/A | [V] DIMENSIONAL OUTLINE DRAWING | ||||
26. MAX. STARTING CURRENT: | 478.3% | [V] CERTIFIED TEST REPORT & WRITTEN STATEMENT | ||||
27. SPECIAL REQUIREMENTS: | N/A | [V] COMPLETE NAMEPLATE DATA | ||||
28. CORE BALANCE CR: | N/A (See Note 6) | [V] SEE INDUCTION MOTORS SPECIFICATION FOR DETAIL | ||||
E. OTHERS (BY VENDOR) | ||||||
1. ACOUSTIC HOOD FITTED | (X) NO | ( ) YES | |||||
2. CERTIFICATION AUTHORITY | N/A | |||||
F. NOTES | 2. CERT. STANDARD & NUMBER | N/A | ||||
1. (*) VENDOR TO CONFIRM | ||||||
2. RATED VOLTAGE: UP TO 150 kW: 400 V | OVER 150 kW ~ BELOW 3000 kW: 6.6 kV | 3000 kW AND ABOVE: 11 kV | ||||||
3. SPACE HEATERS ARE REQUIRED FOR 30 kW AND ABOVE | ||||||
4. 6 RTD (2 SETS PER PHASE – 3 WIRE TYPE 100 OHM) WINDING TEMPERATURE DETECTOR SHALL BE REQUIRED FOR MV MOTORS 1000 kW and LARGER | ||||||
5. VENDOR SHALL COMPLY WITH THE ATTACHED MOTOR TERMINAL BOX HUB SIZE | ||||||
6. MOTORS 3000 kW AND LARGER SHALL BE PROVIDED WITH CORE BALANCE CURRENT TRANSFORMER FOR DIFFERENTIAL PROTECTION | ||||||
7. LRC LIMITING: UP TO 150 kW MOTOR: 600% WITH IEC TOLERANCE, ABOVE 150 kW ~ UP TO 2000 kW: 550% WITH IEC TOLERANCE, ABOVE 2000 kW: ONLY 450% WITHOUT IEC TOLERANCE | ||||||
8. MOTOR SHALL BE EQUIPPED WITH A CANOPY UNLESS AN AIR DUCT, COOLER, OR SILENCER WHICH IS EFFECTIVE FOR A CANOPY IS PROVIDED ON THE TOP MOTOR |
A. GENERAL | C. VENDOR’S DATA | |||||
---|---|---|---|---|---|---|
1. DRIVEN EQUIPMENT: | 10ton x Span 21.9 m | 1. MANUFACTURER: | NAMSUNG MACHINERY | |||
2. AMBIENT TEMPERATURE: | MAX. 45ºC / MIN. 2ºC | 2. FRAME REFERENCE: | 80 | |||
3. RELATIVE HUMIDITY: | MAX. 85% / MIN. – % | 3. FRAME MATERIAL: | ALDC 12 | |||
4. ALTITUDE (SEA LEVEL): | LESS THAN 1000 METERS | 4. FULL LOAD SPEED: | 938 RPM | |||
5. APPLICABLE STD.: | IEC 60034, 60072 and 60079 | 5. LOAD: | 50% | 75% | 100% | S.F |
6. PROJECT SPEC.: | 7T04-EL-00-TS-008 | EFFICIENCY [%]: | 65 | 69 | 71 | 1.0 |
7. AREA CLASSIFICATION: | NON-HAZARDOUS | POWER FACTOR [%] | 39 | 50 | 57.3 | 1.0 |
8. SYSTEM FAULT LEVEL: | 80 kA / 1 sec. | CURRENT [A] | 1.4 | 1.5 | 1.75 | 1.0 |
9. SYSTEM EARTHING: | SOLID | 6. ACCELERATION TIME: | 0.3 sec. | |||
10. DESIGN LIFE: | MINIMUM 20 YEARS | 7. FULL-LOAD TORQUE: | 0.436 kg m | |||
B. MOTOR DESIGN DATA | 8. LOCKED ROTOR TORQUE: | 293.4% | ||||
1. MOTOR RATING: | See Note 1 | 9. PULL-UP TORQUE: | 290% | |||
NAMEPLATE RATING: | 0.42 kW | 6 POLES | 10. BREAK-DOWN TORQUE: | 290.2% | |||
RATED VOLTAGE: | 400 V, 3 PHASE, 50 HZ See Note 2 | 11. LOCKED ROTOR CURRENT: | 8.2 A | |||
SERVICE FACTOR: | 1.0 SYNC. SPEED 938 RPM | 12. LOCK. ROTOR PWR FACTOR: | 27% | |||
2. MOTOR TYPE: | SQUIRREL CAGE INDUCTION | 13. STALL TIME (HOT/COLD): | 0.6 sec. | |||
3. OPERATION DUTY: | S4 INTERMITTENT | 14. TRANSIENT REACTANCE (X’d): | N/A | |||
4. ENCLOSURE TYPE: | IP55 | 15. SUB-TRANSIENT REACTANCE (X’d): | N/A | |||
5. COOLING METHOD: | ( ) TENV | (X) TEFC | ( ) CACA | ( ) TEWAC | 16. SPACE HEATER RATING: | N/A V | N/A W | |||
6. TYPE OF PROTECTION REQ’D: | ( ) TYPE n (Exn) | ( ) TYPE p (Exp) | 17. INSULATION CLASS/TEMP. RISE: | F/75ºC | |||
( ) TYPE e (Exe) | ( ) TYPE d (Exd) | 18. STATOR CONNECTION: | Star | ||||
7. STARTING METHOD: | (X) DOL | ( ) AUTO-TRANS. | 19. TEMP. DETECTOR (WIND./BEARING): | N/A | |||
8. PROTECTION DEVICES: | ( ) FUSE | (X) C.B | 20. VIBRATION DETECTOR: | N/A | |||
9. MOUNTING: | (X) HORIZONTAL | ( ) VERTICAL | 21. MOTOR WEIGHT (NET/SHIPPED): | 30 kg | |||
( ) FOOT | 22. ROTOR/LOAD MOMENT OF INERTIA: | 0.009 / 0.01 kg.m2 | ||||
10. DRIVE SYSTEM: | (X) DIRECT | ( ) GEAR UNIT | 23. BEARING REF. (DE/NDE): | #6005ZZ / #6203DD | |||
( ) V-BELTS | 24. BEARING TYPE: | ANTI-FRICCIONAL (BALL) | ||||
11. INSULATION CLASS: | (X) F | 25. BEARING LUBRIFICATION: | GREASE | |||
12. TEMP. RISE WITHIN CLASS: | ( ) E | (X) B | 26. BEARING LUBRIFICATION INTERVAL: | 30,000 HOURS | |||
13. MAIN TERMINAL BOX LOCATION: | (X) RIGHT | ( ) LEFT | 27. NUMBER OF CONSECUTIVE STARTS: | 2 HOT / 3 COLD | |||
14. ROTATION: | (X) CCW | (X) CW | 28. REQUIRED AIR FOR PURGE: | ||||
15. SPACE HEATER SUPPLY: | N/A | @STARTING (PURGING) | N/A Nm3/min @ N/A bar | |||
16. MAIN CABLE ENTRY: | (X) SIDE | ( ) BOTTOM | @OPERATING | N/A Nm3/min @ N/A bar | |||
17. CABLE CONNECTION: | M25 | 29. Void | ||||
18. CABLE TYPE & SIZE (MOTOR): | M25 | 30. TIME CONSTANTS (HEATING/COOLING) | N/A sec. | |||
19. CABLE TYPE & SIZE (S.H): | N/A | D. ADDITIONAL INFORMATION FURNISHED BY VENDOR | ||||
20. SOUND PRESSURE LEVEL: | 62 dB Mean. @ 1 meter ON NO LOAD | [V] TORQUE/SLIP, CURRENT/SLIP, POWER FACTOR/SLIP CURVES | ||||
21. FRAME EARTH BOSS: | INTERNAL & EXTERNAL | [N/A] TIME – CURRENT and THERMAL LIMIT CURVES | ||||
22. COLOR FINISHING: | RAL 6028 | [N/A] MOTOR THERMAL CAPACITY DATA | ||||
23. TEMPERATURE DETECTION: | N/A | [V] INSTALLATION, OPERATION & MAINTENANCE INSTRUCTION | ||||
24. VIBRATION DETECTION: | N/A | [V] RECOMMENDED SPARE PARTS LIST | ||||
25. SURGE WITHSTAND EQUIPMENT.: | N/A | [V] DIMENSIONAL OUTLINE DRAWING | ||||
26. MAX. STARTING CURRENT: | 468.6% | [V] CERTIFIED TEST REPORT & WRITTEN STATEMENT | ||||
27. SPECIAL REQUIREMENTS: | N/A | [V] COMPLETE NAMEPLATE DATA | ||||
28. CORE BALANCE CR: | N/A (See Note 6) | [V] SEE INDUCTION MOTORS SPECIFICATION FOR DETAIL | ||||
E. OTHERS (BY VENDOR) | ||||||
1. ACOUSTIC HOOD FITTED | (X) NO | ( ) YES | |||||
2. CERTIFICATION AUTHORITY | N/A | |||||
F. NOTES | 2. CERT. STANDARD & NUMBER | N/A | ||||
1. (*) VENDOR TO CONFIRM | ||||||
2. RATED VOLTAGE: UP TO 150 kW: 400 V | OVER 150 kW ~ BELOW 3000 kW: 6.6 kV | 3000 kW AND ABOVE: 11 kV | ||||||
3. SPACE HEATERS ARE REQUIRED FOR 30 kW AND ABOVE | ||||||
4. 6 RTD (2 SETS PER PHASE – 3 WIRE TYPE 100 OHM) WINDING TEMPERATURE DETECTOR SHALL BE REQUIRED FOR MV MOTORS 1000 kW and LARGER | ||||||
5. VENDOR SHALL COMPLY WITH THE ATTACHED MOTOR TERMINAL BOX HUB SIZE | ||||||
6. MOTORS 3000 kW AND LARGER SHALL BE PROVIDED WITH CORE BALANCE CURRENT TRANSFORMER FOR DIFFERENTIAL PROTECTION | ||||||
7. LRC LIMITING: UP TO 150 kW MOTOR: 600% WITH IEC TOLERANCE, ABOVE 150 kW ~ UP TO 2000 kW: 550% WITH IEC TOLERANCE, ABOVE 2000 kW: ONLY 450% WITHOUT IEC TOLERANCE | ||||||
8. MOTOR SHALL BE EQUIPPED WITH A CANOPY UNLESS AN AIR DUCT, COOLER, OR SILENCER WHICH IS EFFECTIVE FOR A CANOPY IS PROVIDED ON THE TOP MOTOR |
A. GENERAL | C. VENDOR’S DATA | |||||
---|---|---|---|---|---|---|
1. DRIVEN EQUIPMENT: | 10ton x Span 21.9 m | 1. MANUFACTURER: | NAMSUNG MACHINERY | |||
2. AMBIENT TEMPERATURE: | MAX. 45ºC / MIN. 2ºC | 2. FRAME REFERENCE: | 112M | |||
3. RELATIVE HUMIDITY: | MAX. 85% / MIN. – % | 3. FRAME MATERIAL: | ALDC 200 | |||
4. ALTITUDE (SEA LEVEL): | LESS THAN 1000 METERS | 4. FULL LOAD SPEED: | 950 RPM | |||
5. APPLICABLE STD.: | IEC 60034, 60072 and 60079 | 5. LOAD: | 50% | 75% | 100% | S.F |
6. PROJECT SPEC.: | 7T04-EL-00-TS-008 | EFFICIENCY [%]: | 73 | 76 | 78 | 1.0 |
7. AREA CLASSIFICATION: | NON-HAZARDOUS | POWER FACTOR [%] | 55 | 67 | 73 | 1.0 |
8. SYSTEM FAULT LEVEL: | 80 kA / 1 sec. | CURRENT [A] | 3.5 | 3.8 | 4.5 | 1.0 |
9. SYSTEM EARTHING: | SOLID | 6. ACCELERATION TIME: | 0.3 sec. | |||
10. DESIGN LIFE: | MINIMUM 20 YEARS | 7. FULL-LOAD TORQUE: | 1.333 kg m | |||
B. MOTOR DESIGN DATA | 8. LOCKED ROTOR TORQUE: | 225% | ||||
1. MOTOR RATING: | See Note 1 | 9. PULL-UP TORQUE: | 185% | |||
NAMEPLATE RATING: | 1.3 kW | 6 POLES | 10. BREAK-DOWN TORQUE: | 306% | |||
RATED VOLTAGE: | 400 V, 3 PHASE, 50 HZ See Note 2 | 11. LOCKED ROTOR CURRENT: | 16 A | |||
SERVICE FACTOR: | 1.0 SYNC. SPEED 950 RPM | 12. LOCK. ROTOR PWR FACTOR: | 22% | |||
2. MOTOR TYPE: | SQUIRREL CAGE INDUCTION | 13. STALL TIME (HOT/COLD): | 0.6 sec. | |||
3. OPERATION DUTY: | S4 INTERMITTENT | 14. TRANSIENT REACTANCE (X’d): | N/A | |||
4. ENCLOSURE TYPE: | IP55 | 15. SUB-TRANSIENT REACTANCE (X’d): | N/A | |||
5. COOLING METHOD: | ( ) TENV | (X) TEFC | ( ) CACA | ( ) TEWAC | 16. SPACE HEATER RATING: | N/A V | N/A W | |||
6. TYPE OF PROTECTION REQ’D: | ( ) TYPE n (Exn) | ( ) TYPE p (Exp) | 17. INSULATION CLASS/TEMP. RISE: | F/75ºC | |||
( ) TYPE e (Exe) | ( ) TYPE d (Exd) | 18. STATOR CONNECTION: | Star | ||||
7. STARTING METHOD: | (X) DOL | ( ) AUTO-TRANS. | 19. TEMP. DETECTOR (WIND./BEARING): | N/A | |||
8. PROTECTION DEVICES: | ( ) FUSE | (X) C.B | 20. VIBRATION DETECTOR: | N/A | |||
9. MOUNTING: | (X) HORIZONTAL | ( ) VERTICAL | 21. MOTOR WEIGHT (NET/SHIPPED): | 64.6 kg | |||
( ) FOOT | 22. ROTOR/LOAD MOMENT OF INERTIA: | 0.064 / 0.078 kg.m2 | ||||
10. DRIVE SYSTEM: | (X) DIRECT | ( ) GEAR UNIT | 23. BEARING REF. (DE/NDE): | #6208DD / #6006DD | |||
( ) V-BELTS | 24. BEARING TYPE: | ANTI-FRICCIONAL (BALL) | ||||
11. INSULATION CLASS: | (X) F | 25. BEARING LUBRIFICATION: | GREASE | |||
12. TEMP. RISE WITHIN CLASS: | ( ) E | (X) B | 26. BEARING LUBRIFICATION INTERVAL: | N/A | |||
13. MAIN TERMINAL BOX LOCATION: | (X) RIGHT | ( ) LEFT | 27. NUMBER OF CONSECUTIVE STARTS: | 2 HOT / 3 COLD | |||
14. ROTATION: | (X) CCW | (X) CW | 28. REQUIRED AIR FOR PURGE: | ||||
15. SPACE HEATER SUPPLY: | N/A | @STARTING (PURGING) | N/A Nm3/min @ N/A bar | |||
16. MAIN CABLE ENTRY: | (X) SIDE | ( ) BOTTOM | @OPERATING | N/A Nm3/min @ N/A bar | |||
17. CABLE CONNECTION: | M32 | 29. Void | ||||
18. CABLE TYPE & SIZE (MOTOR): | TFR-CV 4.0SQ | 30. TIME CONSTANTS (HEATING/COOLING) | N/A sec. | |||
19. CABLE TYPE & SIZE (S.H): | N/A | D. ADDITIONAL INFORMATION FURNISHED BY VENDOR | ||||
20. SOUND PRESSURE LEVEL: | 62 dB Mean. @ 1 meter ON NO LOAD | [V] TORQUE/SLIP, CURRENT/SLIP, POWER FACTOR/SLIP CURVES | ||||
21. FRAME EARTH BOSS: | INTERNAL & EXTERNAL | [N/A] TIME – CURRENT and THERMAL LIMIT CURVES | ||||
22. COLOR FINISHING: | RAL 6028 | [N/A] MOTOR THERMAL CAPACITY DATA | ||||
23. TEMPERATURE DETECTION: | N/A | [V] INSTALLATION, OPERATION & MAINTENANCE INSTRUCTION | ||||
24. VIBRATION DETECTION: | N/A | [V] RECOMMENDED SPARE PARTS LIST | ||||
25. SURGE WITHSTAND EQUIPMENT.: | N/A | [V] DIMENSIONAL OUTLINE DRAWING | ||||
26. MAX. STARTING CURRENT: | 312.5% | [V] CERTIFIED TEST REPORT & WRITTEN STATEMENT | ||||
27. SPECIAL REQUIREMENTS: | N/A | [V] COMPLETE NAMEPLATE DATA | ||||
28. CORE BALANCE CR: | N/A (See Note 6) | [V] SEE INDUCTION MOTORS SPECIFICATION FOR DETAIL | ||||
E. OTHERS (BY VENDOR) | ||||||
1. ACOUSTIC HOOD FITTED | (X) NO | ( ) YES | |||||
2. CERTIFICATION AUTHORITY | N/A | |||||
F. NOTES | 2. CERT. STANDARD & NUMBER | N/A | ||||
1. (*) VENDOR TO CONFIRM | ||||||
2. RATED VOLTAGE: UP TO 150 kW: 400 V | OVER 150 kW ~ BELOW 3000 kW: 6.6 kV | 3000 kW AND ABOVE: 11 kV | ||||||
3. SPACE HEATERS ARE REQUIRED FOR 30 kW AND ABOVE | ||||||
4. 6 RTD (2 SETS PER PHASE – 3 WIRE TYPE 100 OHM) WINDING TEMPERATURE DETECTOR SHALL BE REQUIRED FOR MV MOTORS 1000 kW and LARGER | ||||||
5. VENDOR SHALL COMPLY WITH THE ATTACHED MOTOR TERMINAL BOX HUB SIZE | ||||||
6. MOTORS 3000 kW AND LARGER SHALL BE PROVIDED WITH CORE BALANCE CURRENT TRANSFORMER FOR DIFFERENTIAL PROTECTION | ||||||
7. LRC LIMITING: UP TO 150 kW MOTOR: 600% WITH IEC TOLERANCE, ABOVE 150 kW ~ UP TO 2000 kW: 550% WITH IEC TOLERANCE, ABOVE 2000 kW: ONLY 450% WITHOUT IEC TOLERANCE | ||||||
8. MOTOR SHALL BE EQUIPPED WITH A CANOPY UNLESS AN AIR DUCT, COOLER, OR SILENCER WHICH IS EFFECTIVE FOR A CANOPY IS PROVIDED ON THE TOP MOTOR |
Material Condition:
- Condition: Used
Geography, Logistics & Export Information:
- Region: Egypt
- Dismantling: The location will be responsible for the dismantling scope.
- Loading Capabilities: The location has no loading capabilities.
- Export: Material can be exported. There might be associated customs duties/ local taxes. Information to be checked and informed when an acceptable offer is made – depends on the buyer’s location.
- Local Sales: Local taxes might be applicable if the material is sold in the country.
IMPORTANT NOTE: The seller has not provided a specific price reference and is open to considering all reasonable offers. However, please note that the seller reserves the right to decline any bid at their discretion.
Buyer’s Premium: 10% service fee to be added to the final invoice or invoiced separately by Surpplax Asset Management.
General Conditions of Sale Agreement: The material is being sold “as is, where is. The Buyer must sign the agreement before the material’s release. As soon as payment is confirmed, the Seller will promptly issue a Release to authorize the Buyer to pick up the item and the title will officially transfer from the Seller to the Buyer.
We take great care to provide accurate and detailed information about the assets available for sale. However, we strongly recommend that the Buyer double-check the quantities and conditions listed before collecting material. The amount listed will be subject to plus/minus (+/- 05%) tolerance and no adjustment will be made if within this range. If any discrepancies are noted over +/- 5% of the listed quantities, the Buyer must notify Surpplax before collecting material.